Bed elevator
The fully computerized modular data intellectual network controlled, high; precise and top VVVF (variable frequency speed) technology of "XIWU"elevator fully demonstrate the human intelligence, the more perfect and flexible systematic functions as well. It brings about the more secure, accurate and efficient management and control to the lift operational execution. Its special-purpose modular structure can more conveniently fulfill the updating and upgrading of the elevators in the near future under the conditions of not changing its completion and fully conveyance.
1) The standard decroation: car, car door, first landing door finished with stainless steel. Other landing doors finished with painted steel.
2) Norrow jamb with stainless steel finished.
3) Ceiling - Backed enamel steel and acrylic.
4) Ventilating mode - Direct blast Axial-flow fan
5) Operation panel, outer calling - Hairline stainless steel.
6) Floor display in car - Car operation panel is attached with digital floorlattice display.
7) Floor - PVC lpastic cement floor.
8) VVVF drive system
9)Speed-1.0m/s, 1.5m/s, 1.6m/s, 1.75m/s
10) Capacity-1000kg, 1350kg, 1600kg
Standard function
Automatic operation
The lift automatically runs and stops, opens / shuts the door according to designated command
Operation by operator
The lift automatically runs and stops, manually shuts the door according to designated command.
Overhaul operation
Under repair and inspection conditions, the lift runs at inspection speed through operating "slow up / slow down" buttons.
Upper automatic door-opening
When the lift is electrified and the car is in the door zone, it will open the door automatically.
Automatic door-shut time-delay
After the car door has been opened completely, it keeps the door open condition. It automatically shuts the door after time-delay.
Call for opening of this floor
When the lift is shutting the door or it does not start but has closed the door, when there is any outer
calling from this landing, it will reopen the door.
Safety touch board,optical curtain protection
When safety touch board has been touched or optical curtain has been shaded,it immediately stops
door-shut action and automatically opens the door.
Over-load none door-shut
It does not shut the door in overload. And it is bright from overload lamp. The buzzer rings. It shows
CZ or overload in the car and does not start the lift.
Full-load direct running
When it reaches the rated load, it only responds to internal selection instead of outer calling.
Automatic lighting control
In the stipulated time, if the lift does not receive any travel command, the lighting will a utomatically die out. It automatically opens at command.
Firefight return
When it starts home landing fire-fighting switch, all the commands will be cancelled then. The lif t immediately drives to the designated landing and park there.
Mal-operation removal
Repeatedly operate internal selective button to cancel mal-operation registration.
Main contactor protection
After the lift executes door-shut command, if the door has not been closed within the stipulated time,
it will re-open the door and then shut it again.
Service floor setting
The lift only serves the set floor.
Home landing floor setting
Under the automatic condition, if there is no command within certain period, the car will automatic ally
run to the set landing.
Landing floor, direction display in the car
It shows the landing floor of the lift, the direction where the lift is going to travel in the car.
Direction chosen by driver
The running direction is determined by the driver's directive
Opposite door service setting
Correctly open / shut the door in the corresponding floor according to service setting.
Trouble diagnosis
When there is something wrong in the travel process, it will automatically diagnose the trouble cause,
display in the operation panel and automatically store the latest trouble information.
Safety circuit protection
If safety circuit is disconnected, the lift will immediately stop the travel.
Door interlocking protection
If it closes all of door interlocking, it can then start the lift. If door interlocking is disconn ected or trembled,the lift will stop the operation.
Travel contactor protection
The system can detect whether motor circuit contactor action is reliable or not. If any abnormal condition happens, it will stop the lift travel.
Brake test protection
It implement real-time monitor to the brake open / shut through brake arm test switch. If the brake has been opened improperly, the system will not allow the lift to start.
Terminal speed change and landing floor number correction
After the system detect terminal switch in travel, the lift will be forced to change the speed and automatically correct the landing floor display .
Position-Limit protection
If the system detects limit switch action, it will immediately stop the lift travel.
Limit protection
If the system detects limit switch action, the whole system will immediately lose power.
Over-speed protection
When the lift up / down exceeds 1.2 times of the rated speed, it will cut off control mains and stop the lift travel.
Bed elevator